Porcine Circovirus Type 2 (PCV2) Antibody Elisa Diagnostic Test

Product Details
Customization: Available
Syringe: Disposable Sterile Syringe
Blood Sampling Needle: Disposable Vacuum Blood Sampling
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make at Made-in-china.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory & Trading Company

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2022

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
1200
Year of Establishment
1999-04-02
  • Porcine Circovirus Type 2 (PCV2) Antibody Elisa Diagnostic Test
  • Porcine Circovirus Type 2 (PCV2) Antibody Elisa Diagnostic Test
  • Porcine Circovirus Type 2 (PCV2) Antibody Elisa Diagnostic Test
  • Porcine Circovirus Type 2 (PCV2) Antibody Elisa Diagnostic Test
  • Porcine Circovirus Type 2 (PCV2) Antibody Elisa Diagnostic Test
  • Porcine Circovirus Type 2 (PCV2) Antibody Elisa Diagnostic Test
Find Similar Products

Basic Info.

Animal Anesthesia Machine Control Method
Pneumatic
Application
Detect The Nucleic Acid of Circovirus Type 3 in to
Validity
1 Month
Transport Package
Box
Specification
96T x 5/Box
Trademark
SINDER
Origin
Shandong

Packaging & Delivery

Package Size
15.00cm * 7.50cm * 6.00cm
Package Gross Weight
0.500kg
Lead Time
30 days (1 - 99999 Sets)
To be negotiated ( > 99999 Sets)

Product Description

 

Mycoplasma Synoviae (MS) Antibody ELISA Test Kit

(For external detection use only)

For Animal Use Only

Product Name: Mycoplasma Synoviae (MS) Antibody ELISA Test Kit

Main Component and Composition:

Name

Quantity

(1) Coated MS Assay Plate

96wells x 5

(2) MS Positive Control Serum

(3) Negative Control Serum

(4) Enzyme Conjugate

(5) Wash Buffer (10 x concentrate)

(6) Sample Diluent

(7) TMB Chromogen Substrate

(8) Stop Solution

(9) Instruction Manual

(10) Reagent Reservoirs

(11) Adhesive Strip

1.5ml x 1

1.5ml x 1

55ml x 1

90ml x 1

100ml x 1

25ml x 1

30ml x 1

1

5

5

 

Sample Preparation:

1. Dilute the sample 500 times with the sample diluent (e.g. add 1μl sample into 499μl sample diluent, mix well).

*Note: It is recommended to pre-dilute the sample by 50 times and then diluted by 10 times (for reference only)

2. The wash buffer (10 x concentrate) shall be diluted 10 times by deionized water before use. (e.g. add 9ml deionized water to every 1ml wash buffer (10 x concentrate))

3. Negative and positive control serum shall be directly used without dilution.

Usage:

1. Before use, place the kit at room temperature (15-25ºC) for 30min and restore to room temperature.

2. Take the required amount of Coated MS Assay Plate, and set 2 wells for negative and positive controls respectively.

3. Add 100μl positive/negative control to the positive/negative control well, and add 100μl diluted sample to the sample well, incubate at 37ºC for 30min in shading light.

4. Remove the liquid in each well. Immediately add 350μl Wash Buffer to each well and wash. Repeat wash procedure for 3 times, invert the plate and pat it against absorbent paper.

5. Add 100μl of Enzyme Conjugate into each well, cover the plate sealer and incubate at 37ºC for 45min.

6. Repeat step 4 for washing.

7. Add 100µL TMB chromogen Substrate into each well. Cover the plate sealer and mix thoroughly, incubate at 37ºC for 5 min in shading light.

8. Add 50µL Stop Solution in to each well, mix thoroughly. Measure the Absorbance value of each well at 450nm wavelength of Microplate Reader immediately.

Interpretation of the results

1. Validity of the test: the test is valid when the difference between the average OD value of the positive control and the average OD value of the negative control is > 0.20.

2. The sample OD value is S. The mean value of positive control is Pp, the mean value of negative control is Pn.

3. Calculate: S/P value

4. Judgement: Positive when S/P value≥0.9, negative when S/P value<0.9

Cautions:

1. TMB Chromogen Substrate and Stop solution may be irritating to skin and eyes. Please keep away from direct touch and light.

2. The Coated MS Assay Plate should be recovered from cold storage environment to room temperature before opening the package. The unused Coated MS Assay Plate shall be stored in sealed bag with desiccant.

3. At low temperature, the Wash Buffer (10 x concentrate) has crystal sediment. It shall be heated in a 37ºC water bath for 10-20 min to completely dissolve the crystal sediment.

4. The serum shall be collected according to the routine method to avoid hemolysis or bacterial growth. The frozen serum shall avoid repeated freezing and thawing. In case of turbidity or sedimentation, it shall be centrifuged or filtered for clarification before testing.

5. The components of different batch numbers shall be not mixed.

Package: 96T x 5/Box

Storage and Shelf Life: The kit shall be stored at 2-8ºC for 12 months. The unused plate shall be kept in a seal bag at 2-8ºC away from light, the validity will be 1 month.


Porcine Circovirus Type 2 (PCV2) Antibody Elisa Diagnostic Test
Porcine Circovirus Type 2 (PCV2) Antibody Elisa Diagnostic TestPorcine Circovirus Type 2 (PCV2) Antibody Elisa Diagnostic Test

Shandong Sinder Technology Co., Ltd ('Sinder') founded in April 1999, has a wide range of animal health products. Sinder focus on Animal Health Products, Animal Vaccine, Antibodies, Antibiotics, Feed Additives, Chinese Herbal Product, Pet food, Elisa, and PCR test kit.

Sinder always persists in the core concept of 'The Relentless Pursuit of Increasing Customer Value. ' Based on the animal health to achieve a service provider for ecological construction of agriculture and animal husbandry. Support the efficient and sustainable development of agriculture and animal husbandry. Make food safer and rural areas better!

Sinder is a high-tech enterprise and one of the top 10 veterinary drug manufacturers in China and focusing on the animal health business. At the moment, the company has 35 GMP production lines, 1 CNAS laboratory, 3 national scientific research platforms, and 8 provincial scientific research platforms owned by Sinder.

Sinder has 4 R&D centers located in Qingdao, Zhucheng, and Beijing, China, and 1 laboratory in Silicon Valley in the United States. At present, the company has 1,535 employees including more than 200 masters or above and 18 doctors. Also, the company established extensive technical cooperation with several domestic and foreign scientific research institutes, animal health companies, and domestic veterinary medicine enterprises. Sinder has undertaken 57 national, provincial, and ministerial projects, gained 7 provincial and ministerial science and technology progress awards, presided over or participated in 23 national standards, obtained 23 new veterinary drug certificates(one 1st class new drug), and 60 authorized patents.Porcine Circovirus Type 2 (PCV2) Antibody Elisa Diagnostic TestPorcine Circovirus Type 2 (PCV2) Antibody Elisa Diagnostic TestPorcine Circovirus Type 2 (PCV2) Antibody Elisa Diagnostic TestPorcine Circovirus Type 2 (PCV2) Antibody Elisa Diagnostic TestPorcine Circovirus Type 2 (PCV2) Antibody Elisa Diagnostic Test

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier